Furnace NO HEAT
Upon arrival customer stated they turned the unit on this morning but house wouldn’t heat. Heard a humming sound coming from the unit. Performed diagnostics. Turned unit on and the furnace would go through its start up. Unit did ignite and flames were present but would shut off, error code 270 on the board, indicating flame not sensed. I removed flame sensor and cleaned. Unit still throwing error code. I checked the micro amps and was getting zero. I found a wire on the board loose. Secured it to the board and verified it couldn’t come loose. Unit is heating. I did however find a zone damper motor failed. It’s hot to the touch and is buzzing. I removed the wires from the motor and it stays stuck open. This will need to be replaced for proper operation. I will call Monday morning for pricing, once given I will send over an estimate for replacement.

Furnace Diagnostic
During the inspection, we discovered that the pressure switch wire had been unplugged, which was affecting system functionality. After reconnecting the wire, we tested the system thoroughly and confirmed that everything is operational. There are no major issues to address at this time, ensuring the system is running smoothly. Thank you for your business.

Furnace Tune Up
The furnace was experiencing inefficiencies due to a dirty blower wheel, a secondary heat exchanger, and a soiled evaporator coil. We performed a thorough tune-up, ensuring the filter was clean. Notably, the induced draft motor was over amping at 0.46 amps, exceeding its rated capacity. The customer acknowledged the need for future repairs but opted to delay replacements until necessary. The unit is currently functioning and heating.

AC Leak Search And Repair
A leak was detected, prompting us to conduct a thorough search and repair. We efficiently addressed the issue while handling a 410A call. Our focus was on resolving the problem effectively, ensuring optimal performance of the HVAC system. We took proactive measures to prevent any potential future issues, delivering reliable service for the customer's peace of mind.

AC Parts Replace
Return visit 10/7/26: performed the uv light search. No evidence on the indoor coil. The condensate tray had no traces of dye. I checked the outdoor coil and all braze joints. No signs of a leak there. I checked both the liquid line schrader core and suction line. Found dye inside of the locking cap for the suction line. Inside of the valve there was a lot of dye showing. I removed schrader core and found debris on the gasket. Cleared debris and placed back in. The leak was coming from the suction side. The leak was very minimal but over the course of 9 years, refrigerant will leak out. I checked pressures and compared to previous visit. They look about the same. No other leaks detected. Unit is cooling at this time.

2 Membership Furnace Tune Ups
Two furnaces were in need of tune-ups, with one located in the basement and the other in the attic. We performed the necessary maintenance, renewing two memberships for a total of $290. The basement furnace had its filter changed regularly, while the attic furnace's filter history was unknown, prompting us to ensure it received the necessary care. We completed the work efficiently, allowing Chris to return home after dropping off his kids.

Furnace Tune Up
During the inspection, we discovered water leaking from the collector box. We tightened the plug on the left side, which resolved the leak. We performed a furnace tune-up, noted that the filter is ready for replacement, and the humidifier pad is in good condition. The blower wheel, while slightly dirty, can be cleaned. The unit is operating well and is prepared for winter. Please see the attached form for further details.

Furnace Tune Up
Performed furnace tune up. Filter is still clean. Recommend replacing in the next few months. The humidifier pad is in ok condition. Replacement recommended. Customer will order some and replace. The solenoid valve is not fully opening. It’ll open for about a second and allow a steady stream but then will go to a fast drip. This can be replaced as well. No issues to address today. System is operating properly and is heating at this time. Customer has concerns that their water heater isn’t heating like it used to. They are interested is possibly replacing to be proactive. The unit was installed October 2016. Average life span of a water heater is 10-12 years. Sending over an estimate for replacement.

Furnace Maintenance
Performed furnace tune up. Replaced the filter with one provided. During the visual inspection I found the blower wheel dirty. It’s not horrible but cleaning is recommended. No other issues to address. Unit is heating properly at this time. I replaced the humidifier canister. Tested operation, unit is now ready for the winter.

Furnace Tune Up Membership
To ensure optimal performance during the changing seasons, we conducted a thorough assessment of the furnace as part of our Tune Up Program. This included checking and replacing filters, inspecting ignition systems, and testing overall efficiency, ultimately enhancing the unit's reliability for the upcoming months. The renewal in spring prepares the system for peak performance.

Air Conditioner And Furnace Tune Up Maintenance
We identified significant issues with both the furnace and AC unit. We performed a thorough tune-up, replacing the filter and rinsing the coils. However, the furnace had rust inside the burner cabinet, an overamping draft motor, and a dirty blower wheel. The AC compressor showed high startup amps and a low capacitor rating. Due to the age of the units, replacement with a more efficient system was recommended.

AC Installation
The old AC unit was no longer cooling efficiently, necessitating an upgrade. We installed a brand-new air conditioning system that comes with a 10-year parts and labor warranty, as well as a 10-year compressor warranty. This ensures long-term reliability and peace of mind for the homeowner.

Air Conditioner Diagnostic
This system had a filter that was installed backwards and creased. This was creating a whistling noise when the unit was running. I replaced the filter and ran the unit to ensure noise was not a mechanical issue. System is sounding great. Thank you for your business!

Two Air Conditioner Diagnostics
Upon arrival customer stated the unit that cools the main level quit working. He replaced the capacitor and it began cooling. He noticed frost in the suction line outside. The other unit for the top floor did seem to keep up. Performed diagnostics. I found the filter for the main level dirty. The filter is already very restrictive as is. This caused the coil to freeze up. I recommend using a merv 7 or 8 and replace every month. Unit is operating ok. The upper level unit I had found it very low on refrigerant. Unit is 20 years old. Spoke with customer about options. Right now he just wanted to top it off to get them through the remainder of summer. When we come back we will compare pressures from today to the fall. Added 3lbs of refrigerant. Got the Subcool as close to 6° as possible. Unit is putting out a 21° delta t. Unit is cooling at this time.

A/C Diagnostic
System is 100 percent frozen from inside to outside. Unit is 24 years old and extremely dirty. Unable to perform proper diagnostics today due to system being frozen.

A/C Tune Up
Performed ac tune up. Filter is clean. The indoor unit is looking great. The outdoor unit coils were rinsed. All electrical components are testing good. I couldn't check pressures due to my gauge not being able to screw onto the suction side port, the threads for the port were cross threaded. However the delta t was within range. System is cooling at this time.

Air Conditioner Diagnostic
This 2004 carrier air conditioner is currently running with an electrical fault in the compressor motor, and low refrigerant charge. System currently only has 86 psi on the suction side of the system.

Air Conditioner Maintenance
The current air conditioning system, 24 years old and struggling, was inefficient due to a rusted evaporator coil and previous attempts to replace components. We assessed the situation, finding a low refrigerant charge and suction pressure at only 59 psi. A discussion on potential replacement options was held, providing the homeowner with insights for a viable long-term solution.

A/C Diagnostic
During this appointment, I discovered that this system paired with a dirty condenser coil that was blanketed with cotton, as well as a dirty filter was no longer flashing and cooling properly. After discussing details built into the club membership, Jonathan decided to enroll in the maintenance program as well as have me replace the filter during this appointment.

AC Tune Up
The noisy chatter from the Armstrong air unit was traced to a warped plastic cap. We addressed this by installing isolation pad strips beneath the unit to minimize noise. We also noted that the contactor and dual run capacitor are degrading, linked to a worn compressor motor and corroded evaporator coil. Proactive repair recommendations were documented for future reference.

A/C Tune Up
This 2014 Armstrong air is currently running at this time without faults. Plastic cap on top of the unit was warped and creating a chatter noise. I was able to stick isolation pad strips underneath To reduce noise for Barry while I was scheduled out. Contactor on unit is beginning to deplete as is the dual run capacitor due to worn compressor motor and rusted out evaporator coil. During this appointment, we spent time going through the service report together. Proactive repairs have been produced and are attached to job for future reference. Thank you for your business Barry!

A/C Part Install
Installed compressor saver kit. Tested operation and unit is cooling at this time.

Air Conditioner Tune Up
While inspecting Steve’s air conditioning system from 1999, we found significant rust in the heat exchanger due to years of malfunctions and freezing issues with the air conditioner. After evaluating the refrigerant charge, it became clear that the unit was barely functioning. We discussed the necessity of a full system replacement for both the furnace and air conditioner, emphasizing the importance of regular maintenance for the new system.

Air Conditioner Maintenance
Performed ac tune up. Replaced filter with one provided. The blower wheel is caked with dust. A cleaning is recommended. The indoor coil looks ok, wasn’t able to get the cabinet door open due to location so I couldn’t see how much rust is built up. The condenser fins are in bad condition, a lot of it is bent. The unit is not level, but customer will adjust it. Pressures were looking a bit low but not worth adding any into this 27 year old unit. The disconnect needs replaced. When it is pulled the interior with the wires moves around and almost comes all the way out. This is a safety hazard for technicians that work on the equipment. The unit is cooling at this time.

Furnace & AC Tune Ups
Performed furnace and ac tune ups. Filter is replaced by the customer. The units are 4 years old. There is only minor things that were discovered today but not going to cause an issue at this time. I spoke with customer about the things that are an area to monitor. Went through the inspection forms with the customer. I will be sending over my recommendations. The furnace and ac are operating within manufacture specs and are heating/cooling properly at this time. Please see attached form for further details regarding today’s visit. Spoke with customer about the club membership. Customer will speak with wife and make a decision.

A/C Tune Up
Performed ac tune up. The furnace had 2 filters installed. One was a 20x25x5 and the other was a 20x25x1. The 5 inch filter was dirty, so I removed it and left the 1 inch filter in. 2 filters in the unit puts a lot of strain on the blower motor and reduces airflow. Recommend using one filter. The indoor coil was clean, the secondary heat exchanger had some dust build up but not reducing performance. The blower wheel was pretty clean. The outdoor coils were in good condition and not impacted with cottonwood or debris. During my testing I found the capacitor was reading pretty low. I replaced with new. Found no other significant issues with the system. Unit is operating within manufacture specifications and is cooling properly at this time. Please see attached form for further details regarding today’s visit.

Mini Split Heat Pump Installation
To enhance indoor comfort, we installed a mini-split system that efficiently regulates temperature throughout the garage. We provided a 5-year labor and parts warranty, along with a 7-year compressor warranty, ensuring peace of mind for our customer. The installation was completed with precision and care for optimal performance.

Furnace Parts Replacement
To ensure optimal performance, we installed a new two-stage gas valve during the appointment. We carefully adjusted the gas pressures for both low and high stages, ensuring everything functions efficiently. After completing the work, we found no further issues at this time. Thank you for your business.
AC Diagnostic
The heating system was not functioning properly due to a faulty contractor and thermostat. We diagnosed the issue and replaced both components, ensuring everything was in perfect working order. The system is now running smoothly and efficiently.
AC Install
After encountering a condenser compressor failure, we installed a new Honeywell J-Stat equipped with Honeywell t-stat. To ensure peace of mind, we provided a 10-year PATS/Labor warranty and a lifetime unit replacement program. We've enhanced the system's efficiency, promising reliable performance for years to come.
What Fort Collins homeowners are saying
A 5★ average rating from 8 verified reviews.
Isaac did a great job with the Fall tuneup. Found and fixed the cause of an issue our prior HVAC provider had suggested we just "watch". He was professional, personable, and explained his findings clearly. It was our first time with Long HVAC, and it was a very good one.
Long Heating and Air recently installed a heat pump in our garage. Dylan and Jessica were wonderful to work with and we are very happy with their work, bid process and willingness to answer questions quickly along the way. They came highly recommended by a realtor friend who raved about their company.
Very prompt and thorough service!
Phil Long‘s AC service was great. They were able to come out in the same day. Dylan, the AC technician, was extremely knowledgeable and explained everything so that we could understand it. The price was great and the service was excellent. We will recommend them to all of our friends.
We have used Long Heating and Air for a few different projects and have been 100% satisfied. Their service is fairly priced, prompt, professional and their staff is respectful and knowledgeable. A++ service!
Phil and his crew helped us with our basement finish. Their communication was clear and timely. The work was completed exactly as we agreed, and the quality was excellent. Phil was great to work with in all phases.