Real work completed for homeowners in Loveland and the surrounding areas.

Furnace Maintenance

Furnace Maintenance

On arrival, found filter very dirty and packed off. Replaced today and would recommend replacing every 30-60 days. Gas pressures were set high and out of range as well. Adjusted down and back into specs. Found evaporator coil above furnace for AC is dirty as well. While inspecting heat exchange, found delamination and scaling beginning internally. This is likely caused by the higher temps in heat exchange due to higher gas pressure and low air flow. No failures found in heat exchanger today but would recommend inspecting annually for any changes. There is humidifier installed on the system but I could not remove door to inspect humidifier pad. There is no damper installed in the bypass either. The humidifier was running but could not test how well. Turned humidifier off today and will send quote to remove and/or replace current one.

Furnace NO HEAT

Furnace NO HEAT

Upon arrival it was stated the unit will run for a few minutes and shut down, house would not heat up. Performed diagnostics. Found thermostat calling but furnace wasn’t running. Error code 13 was present indicating limit lockout: “limit or rollout switch open longer than 3 minutes”. Unit started up after reset. Ran for about 20 seconds before error code 31 (pressure switch opened or is stuck open” Heard water gurgling inside of the induced draft motor. Removed and drained. Found a wasp nest inside of the flue pipe. Reset unit and it satisfied the thermostat. Proceeded with a tune up. Filter is clean. Today I found the blower a little dirty and the secondary heat exchanger dirty These can be cleaned. Sending estimate. Unit is in working order given its condition. Unit is showing its age with the heat exchanger having heat stress points. However it’s heating.

Furance Tune Up

Furance Tune Up

Performed furnace tune up. Filter is clean. The unit is in amazing condition and is operating without any issues. No issues to address. Unit is heating at this time.

Furnace Tune Up

Furnace Tune Up

This six-year-old Lennox furnace is still running flawlessly. I discovered no major issues to address at the time of my appointment. During this visit we spent time going through the report and have discussed details included within the club membership for future service and savings on repairs and cleanings. Thank you so much for your business!

Job in Loveland

Experiencing inconsistent cooling, we performed an AC tune-up to enhance efficiency and performance. Our service included checking refrigerant levels, cleaning the coils, and ensuring all components operated smoothly. Additionally, we presented the benefits of our membership and collected the fee of $145 for this essential maintenance. This proactive approach helps prevent future issues.

AC Tune Up

AC Tune Up

Performed ac tune up. Filter is clean and replaced by customer. During the visual inspection I found no issues. The condenser coil was rinsed. Refrigerant pressures are within spec. Unit is operating properly at this time. Please see attached form for further details regarding today’s visit.

Furnace And AC Tune Up

Furnace And AC Tune Up

Performed ac tune up. Filters are clean and didn’t need replaced. The blower wheel is a little dirty. Right now it’s not affecting performance. The outdoor coils were rinsed and are now free of debris and cottonwood. Customer had concerns with the clear tube outside at the condenser that is black, the unit spends majority of the day in direct sun light. The clear vinyl tubing is for the thermostat wire. Customer is going to replace it and I recommended putting black pvc tape that’s up rated to protect the thermostat wire more. The unit is operating within manufacture spec and is cooling properly at this time.

Furnace & AC Tune Ups

Furnace & AC Tune Ups

Performed furnace and AC tuneup. Replaced filter with customer provided. Replaced the #35 humidifier pad with one provided. Tested functionality of the humidifier. Found no major issues with either unit. Tested the heat pump mode. Unit heats as intended. System is both heating/cooling at this time.

Air Conditioner Diagnostic

Air Conditioner Diagnostic

Air conditioner is severely low on refrigerant, there is only 15 psi on the suction side under operation and the system is running at over a 100° Superheat. There’s clearly a leak somewhere due to the age and era of the air conditioner the probability of it being in the evaporator coil is fairly high. Due to cost and availability restraints on R22 systems, repair and timeframe are both very difficult. If repair is the route that you two choose just be aware that we will have to source equipment and that could take some time if a coil ends up being the culprit of the leak.

A/C Maintenance

A/C Maintenance

During the tune-up, we discovered that the condenser coils were completely clogged with cottonwood, significantly impacting performance. After rinsing the coils, we conducted standard checks and found the refrigerant pressures to be adequate, albeit affected by the low heat load. The system is currently maintaining the desired temperature of 65°, and we advised the homeowner to monitor its operation.

Furnace Diagnostic

Furnace Diagnostic

The gravity furnace is leaking out of the seams of the heat exchanger. I started it and within a minute of runtime my meter was climbing to over 100 ppm coming right out of the top seam of the heat exchanger. Homeowners are not interested in fixing it and are now going to be going down the route of installing a mini split system but say they are not sure how they are going to pay for it and will be starting with upgrading their electrical panel first. They say they will call us back when they are ready to have us come back out with estimates.

Furnace Diagnostic

Arrived at the Torres household for a no heat diagnostic. System is a 21 year old Trane. I found the acute issue today being the flame sensor has degraded enough to not detect flame signal. Today I pulled and cleaned that in order for the furnace to be operational. I also found a blower motor that has broken the grease seal and is leaking out. This is causing a high amp draw and consequently burning the circuit board. The heat exchanger is showing signs of its age as the rings are rusting and will eventually need addressed.

Furnace Estimate

Furnace Estimate

After identifying the need for a new furnace, we conducted a thorough inspection of the existing system. Our evaluation provided the homeowner with an accurate estimate for a modern heating solution, ensuring they have the information needed to make an informed decision among multiple options. We focused on outlining the benefits of the proposed furnace to enhance their home's efficiency.

Furnace Diagnostic

No heat Found pressure switch error code. Condensate (80%) chuck got sucked in to induce draft motor port for pressure switch tube. Cleared out and tested. Everything working at this time. Thank you!

Furnace Parts Replace

nstalled AprilAire 16x25x4 (model 410) filter rack and tied into existing duct work. Wiped down and vacuumed out furnace and blower wheel/blower housing. Cleaned evaporator coil as best as possible. This coil is a rheem and cannot access entire underside of coil to clean without complete removal. Was able to clean sides and used foam cleaner on the rest of the coil where it was not accessible. Tested system when finished and everything is running well at this time. Recommend replacing filter every 6-12 months depending on usage of furnace/AC.

Exhaust Fan Diagnostic

The exhaust fan flap was not opening properly, preventing effective ventilation. We repaired the flap and ensured it was functioning correctly. Additionally, we inspected the attic for potential leaks in both the roof vent and exhaust fan piping to ensure everything was secure and operational.

What Loveland homeowners are saying

A 4.7★ average rating from 3 verified reviews.

Jim W
Oct 28, 2026

After many years of less than great experiences with other HVAC companies, I have found the one I will trust long term! Long Heating and Air did a very thorough, professional job getting my furnace functioning at 100% again. Isaac explained everything as he progressed. He was thorough, knowledgeable, and honest. A great service value at a fair price.