Serving Milliken, CO

Local contractor in 80543

Milliken, CO · 80543 11 local projects 2 reviews 5 avg. rating
See our recent work

Recent projects near 80543

Real work completed for homeowners in Milliken and the surrounding areas.

Furnace Diagnostic

Furnace Diagnostic

Upon arrival, it was stated the unit upstairs on the west side keeps shutting down due to the wet switch. They reset the switch and unit comes on. This has been an issue before during the summer. This time it’s been happening for a few days now. Today, the unit was running. Wet switch not tripped, with the ongoing issue with this wet switch, I replaced the faulty switch. Advised them to let us know if it happens again. I checked for flying ants inside of the inducer and the collector. Didn’t find any. Tested operation of the heat pump and the backup heat. Unit is heating at this time.

Warranty Thermostat Diagnostic

Adjustments were necessary due to overheating concerns with the thermostat. We changed the brightness settings and configured the screen saver to display a blank screen. Additionally, we calibrated the system down by 3 degrees and applied putty behind the thermostat for enhanced stability.

5 Furnace Tune Ups, 3 Mini Split Tune Ups, Dehumidifier Tune Up

5 Furnace Tune Ups, 3 Mini Split Tune Ups, Dehumidifier Tune Up

Completed furnace tuneups on systems. I did not change any filters on the furnaces as they were just replaced in June. Left spare filters by each unit and spoke to Matt about having him replace them in December. I did replace the 16x20 AprilAire fresh air filter for dehumidifier in pool room as that was dirty. All furnaces were cleaned and tested in specs. The upstairs East and West furnaces required more time to tear down and clean out due to flying ants clogging them up. I had to remove the electrical and gas on the west side system in order to remove induce draft motor and clean out collector box, motor and drains throughly. I also removed ID motor and drains on East system. The West system was completely clogged up with ants. I did my best to clean it and clear it at this time but there may be more that accumulate until it gets cold and cannot guarantee there will not be issues and may need cleaned out again. I spoke to both Matt and Melissa about this. Moving forward, I will let office know to schedule these fall tuneups after the weather gets colder to hopefully avoid potential issues with the ants. Tested heat on dehumidifier and got the wired controller for the dehumidifier to work again. Reset the unit and reset plug on board inside the dehumidifier. Working at this time. (I tried calling Desert Air tech support for reason it may be happening, but have not received a call back after 2 1/2 hours).

Furnace Tune Up

Furnace Tune Up

Performed furnace tune up. Replaced filter with customer provided. I wiped down the interior and exterior of the furnace. The heat exchanger was inspected and look good for the age of the unit. No cracks or fractures. The temp rise is within range. No major issues discovered. Unit is ready for the heating season.

A/C Diagnostic

A/C Diagnostic

The HVAC unit stopped functioning, which led us to identify a burnt wire at the incoming power disconnect. We replaced the damaged contactor and conducted thorough diagnostics. After testing, we discovered the unit was low on refrigerant, so we added 12.25 oz, improved the subcooling to approximately 9°, and achieved a delta t of 19°. The system is now cooling effectively.

Byepass Humidifier Install

Installed April Aire 620 humidifier. Wired to humidify anytime fan is operating if there is a call for humidity at humidistat. Winter time - set damper on humidifier to “winter” and set dial on humidistat (located just above humidifier) to desired humidity level (35% recommended). Summer time- set damper on humidifier to “summer” and turn dial on humidistat to “OFF” Will need to purchase HydroCore Water Panel for model 620 to replace humidifier pad. Recommended every 1-2 heating seasons based on use. Tested, set water and checked for leaks. Everything working at this time.

Air Conditioner Maintenance

Air Conditioner Maintenance

We identified severe issues with a 9-year-old AC system, including a blower wheel covered in debris and disintegrated condenser coil due to dog urine. To address the problems, we discussed potential repair solutions. A comprehensive plan for future maintenance was also recommended to ensure optimal system performance.

AC Tune Up

AC Tune Up

This 11 year-old carrier for the Miller household is still currently running well. Only issue discovered is that run capacitor is beginning to deplete however given the minimal amount of running on this air-conditioning system, I explained to Lorraine today that I am not concerned at this moment. System was thoroughly cleaned and filter was changed during today’s appointment. Thank you for your business!

AC Diagnostic

AC Diagnostic

Upon arrival, customer stated they turned on the cooling Wednesday. They heard the furnace kick on, but no cool air was coming out of the vents. The temperature in the house was not dropping. Performed diagnostics. The house is at 62°. I turned on the heat to allow the temperature to go up so I can test the AC. I noticed a sound coming from the blower compartment. Shut unit down. Found the blower wheel was scraping up against the housing, one of the mount legs on the blower motor body is beginning to separate. After long extended usage, it will completely separate and will damage the wheel and motor. Blower motor will need to be replaced. Switched unit over to cooling and went to the outdoor unit found it not running. Checked voltage at the contractor, 0 V was present. Located the breaker panel and found the AC breaker was off. Turned it on unit fired up and began cooling. Due to the outdoor temperature of 46° and the indoor temp at 63°, temperatures and pressures are not gonna be accurate. Informed tenant to let landlord know if the unit is not keeping up with demand. Unit is operating at this time. I recommend having an annual tune up for both the furnace and ac.

Installation Furnace, Heat Pump, And Tankless Water Heater

A malfunctioning heating system prompted us to install a replacement furnace and a new heat pump, enhancing the home’s efficiency. Additionally, we installed a Navian tankless water heater, backed by a 10-year parts and labor warranty, along with a lifetime warranty for the heat exchanger and compressor unit. Rebates from Xcel Energy may provide $3,180, contingent on ductwork conditions, bringing total costs to $26,183.21 after rebates.

Full HVAC System Install

Full HVAC System Install

After noticing inconsistent heating, we installed a new heat pump and furnace to enhance energy efficiency and comfort. This job included a robust 10-year part and labor warranty, along with a lifetime unit replacement guarantee on the heat exchanger and compressor for lasting peace of mind.

What Milliken homeowners are saying

A 5★ average rating from 2 verified reviews.

Jeannette Hopperstad
Jan 29, 2026

It was a good experience and the service people were very friendly and easy to work with.

Bob
Dec 27, 2025

Just had a new furnace and heat pump installed. Such a pleasing company to work with. Every single person from start to finish was so helpful and professional. We were kept informed at each and every step from start to finish. Any time I had any questions or concern the guys would patiently take time to answer no matter how dump a question I asked. The install was went extremely well and was as smooth as could be. Communication was great. We knew exactly when they would start, what work would be done and when they expected to finish. After completing the job they left the area cleaner than when they started. It’s hard to find a company these days with this level of costumer service. Highly recommend Long Heating and Air.

Also serving nearby areas

We provide the same trusted service to all of the surrounding ZIP codes.