Serving Timnath, CO
Local contractor in 80547
Recent projects near 80547
Real work completed for homeowners in Timnath and the surrounding areas.

Furnace Tune Up Membership
The humidifier needed verification and maintenance to ensure optimal performance. We replaced the air filter with a Honeywell 20x25x4 and tested the AprilAire Steam Canister Model 80. Additionally, we reviewed the thermostat operation, adjusting the humidity level to a comfortable 40%. There was no charge today, and we will follow up in the spring to renew membership and perform an AC tuneup.

Furnace Tune Up
A routine furnace inspection was conducted on a 2018 Bryant model. We performed a thorough tune-up, ensuring everything was functioning optimally. The old air filter was replaced with a customer-supplied filter (24x24x1). Additionally, we discussed the benefits of renewing the maintenance membership and provided a convenient payment link.

Furnace Diagnostic
This home is in an area the get power surges. Diagnosted that the transformer was burnt up, humidifier canister needed replaced and zone damper needed to be replaces. Replaced zone first motors today, re wired humidifier and replaced humidifier canister. Wired in transformer and have system tested and cycled to ensure all zones are now opening and closing properly. Humidifier is set to run at 30% for the time being. No further issues to address at this time.

Furnace Tune Up X2
The 16 year old Trane furnace here has a failed heat exchanger that is cracked. The new 2024 Amana is running flawlessly at this time. New filters installed and humidifier is set to run for the main floor. All issues on the Trane furnace have been documented in the past years.

Furnace Tune Up
Both furnaces very clean and running/testing in specs. Both humidifiers operating properly and Kevin takes care of replacing canisters. I checked electrodes in both humidifiers and they are already the “o” shape (not the “D” shape) and are good. I did replace the air filter for the main level system with a filter on site and recommend filter replacement for basement system.

Furnace Part Replacement
Performed repair. Removed collector box and stripped away the old gasket. Installed new. Installed new inducer gasket as well. Tested unit multiple times to see if it will leak water. No water present and it’s all going to the drain. Advised customer to monitor for the next few days. He will let us know if anything changes. Unit is heating.

Furnace Tune Up
Performed furnace tune up. Filter is clean. Visually the unit is in great condition. I did find that the humidifier was not coming on with the heat. Made a wiring adjustment to get it to come on when needed. Wired it up directly to the humidifier terminals on the control board and removed the transformer. It’s set for 30%. Unit is operating properly and heating at this time.

Furnace Tune Up
This 9 year old unit is running hotter than hoped for due to the materials that get around the cartridge filter. Secondary heat exchanger and blower wheel are dirty and restriction of airflow causes the system to operate less efficiently. Recommended cleanings would be secondary heat exchanger and blower wheel. Professional recommendation would be to install premium five inch filtration system to prevent this from happening in the future. Due to a lack of airflow across heat exchanger there is high amps pulled on the induce draft motor and rust occurring internally on the heat exchanger. This is all common for a 9 year old builder unit with cartridge filtration. Spent time discussing details with Jill this morning.

Furnace Tune Up Member
Performed furnace tune up. Filter is very dirty, customer will go get some today and replace. The model 80 humidifier canister is in bad condition, replacement is needed. Customer will get one and install. If any issues they will call us for assistance. During the visual inspection, I found the blower wheel and secondary heat exchanger are dirty, cleaning recommended. With more frequent filter changes after cleaning, this will prevent them from getting dirty. In the current state the furnace is heating.

Furnace Tune Up
Performed furnace tune up. Filter is clean and is replaced every 2 months. Tenant stated the filters aren’t ever really dirty when they change them. Today I discovered the blower wheel and secondary heat exchanger are dirty. Cleaning recommended. Also advised to get a duct cleaning and a filter system upgrade to prevent furnace from getting dirty after cleaning is performed. In its current state, the furnace is heating.

Furnace Tune Up X2 Tankless Flush
2x furnace Tuneup Tankless water heater flush. Tankless- flushed water heater for approximately an hour. Removed and cleaned filters. Cleaned ignitor and flame sensor. Reassemble and tested. Everyone looks good at this time. Both furnaces are running well and testing in specs. There is some light dust build up on blower wheels and secondary heat exchangers but everything testing in specs. Air filters were clean on both systems and humidifiers/ humidifier pads are both ready for winter. Will need to open damper on humidifier upstairs and set dials on humidistats (35% recommend when ready to use.

Membership Furnace Tune Up
During our visit, we performed a thorough furnace tune-up to ensure optimal heating performance. We replaced the air filter with one provided and conducted a visual inspection of the unit. Notably, we observed dust accumulation on the blower wheel and will monitor it for future cleaning. The heat exchanger was found to be in good condition, and humidity levels are fully operational. The unit is now ready for winter, and heating is functioning smoothly. Please see the attached form for further details regarding today’s visit.

Furnace And AC Tune Up
Upon inspection, we identified a common issue in new construction: the cartridge filter at 20x25x1 is ineffective at preventing small particulates from accumulating on the blower wheel and secondary heat exchanger. To address this, we recommended replacing it with a 5-inch wide gasket filter, ensuring better protection and reducing future cleaning costs. Both the furnace and air conditioner are functioning well, and all other measurements are in excellent condition. We also discussed options for filter upgrades and a club membership for future savings.
Job in Timnath
To ensure optimal performance of the heating system, we conducted a comprehensive furnace tune-up for the membership renewal. This included inspecting and cleaning critical components to enhance efficiency and safety. We also checked for any potential issues, allowing for smooth operation throughout the heating season.

Furnace Tune Up
Performed 2x furnace tune ups. Filters were clean and replaced by customer. We spoke last time I was here about the secondary heat exchanger for the basement unit being dirty. No change in condition today. Cleaning recommended. Other than that both units are operating well and heating at this time. Please see attached form for further details regarding today’s visit.

Furnace Tune Up Membership
Performed furnace tune up. Replaced filter. Heat exchanger is showing signs of wear and tear. Normal for the age and type of equipment. Humidifier is functioning properly. No major issues to address. Unit is heating at this time. Please see attached form for further details regarding today’s visit

Furnace Tune Up Membership
System is running without active faults. Thoroughly cleaned internals and adjusted gas pressure to specs. Induce draft motor pulls high amps and the secondary heat exchanger is packing off due to in effective filtration. Other measurements look good for the age. No major issues to address at this time

Air Conditioner Diagnostic
During the diagnostic, we identified that the system had not properly flashed the refrigerant charge over the past year, resulting in higher static pressures and electrical faults in the compressor motor. We discussed these findings and noted that the oversized system likely contributed to significant wear and tear. Recommendations for interior cleanings, including the blower wheel, secondary heat exchanger, and evaporator coil, were also provided.

Air Conditioner Diagnostic
During our visit, we serviced a 15-year-old Reem air conditioner for Skip, addressing several issues typical of a builder series system of that age. We ensured the system is currently running smoothly while identifying areas that may need future attention. Thank you for choosing us for your HVAC needs!

Furnace And Heat Pump Installation
We completed a full system installation to enhance electrical efficiency for the property. The job required us to secure the necessary permits, ensuring compliance with all regulations. With precision and care, we finalized the setup, ready for use once completed. Daniels Electric was on-site at 11 AM on Friday to ensure a smooth process. Thank you for choosing our services!
AC Diagnostic
Water overflow from the evaporator coil drain was traced to excessive rust buildup in the P-Trap, which obstructed proper drainage. To address this, we cleared the drains using nitrogen. During our inspection, we discovered a significant failure in the secondary heat exchanger, characterized by calcium growths from acidic condensation. Two options for resolution include replacing the heat exchanger under Carrier's warranty or replacing the furnace altogether.

Warranty Parts Replace
Installed P traps for all three units verified that each unit was not siphoning back to the secondary. Watched water come out of the primary drain line.Called and confirmed with Dylan that each P trap does need a vent. Went outside and verified that all three units were on and cooling.

Furnace And Air Conditioner Tune Up
Performed ac and furnace tune ups. Filter is clean and didn’t need replaced. Furnace: blower wheel and motor are clean. The primary and secondary heat exchanger are clean. Inspected the heat exchanger and it has some heat stress but nothing major. Humidifier is working. The pads are the wrong size. #35 water panel is needed for this unit. However, I was able to make the pads they left work. No issues. Unit is heating at this time. AC: Rinsed the coils off. During start up of the unit, it’s pulling high amp draw and the compressor has a rough startup and shut down. I recommend installing a hard start kit to lessen the amp draw and it’ll help with a softer startup/shut down. The capacitor is reading lower that manufacture allowance. It’ll get through the season but should replace by next year. Unit is cooling at this time.

A/C Diagnostic
Upon assessing the malfunctioning system, we found it was freezing up due to a severely low refrigerant level. We turned off the unit, opened the coil, and allowed the fan to thaw the blockages. Gauges confirmed significant refrigerant loss, likely from a rusted evaporator coil. We discussed options for repair and replacement, considering the age of the R-22 system.

A/C Tune Up
Performed ac tune up. Filter was replaced by the customer not long ago and is still clean. During the visual inspection, I found the blower wheel and secondary heat exchanger beginning to get dirty. A cleaning is possible. The outdoor coils were clogged with cottonwood. This was causing the condenser fan motor to speed up due to the unit suffocating. After I cleaned the coils, the sound went away. The unit seemed to now operating without any issue. System is cooling at this time.

Furnace Diagnostic
Flue was obstructed by the grill and cover that was placed next to the house. Wind had blown the cover against the flue. This was tripping the furnace due to in effective draft capabilities. After removing the cover from in front of the flue the system fired rite up and ran correctly for the remainder of my visit. Alyssa and I discussed the club membership for future service and savings as well while I was out due to no maintenance being performed in the past. Alyssa thank you for your business!

Furnace Tune Up
Arrived for furnace service. System is original to the home, builders grade Bryant. The furnace is running but I did find several issues. The inducer motor is over amping at 0.5, the secondary heat exchanger is 3/4 completely plugged with animal hair and debris, the heat exchanger is rusted and corroding, circuit board is getting hot and starting to char, and lastly I measured 3ppm co at the register closest to furnace. It would bounce from 1-3 but never saw it go over 3. See report for photos
Humidifier Diagnostic
Arrived for a humidifier diagnostic. Steam humidifier was turned off. Turned unit on and tested functionality and humidifer is running within spec.

Furnace Tune Up
This 2018 Carrier is running at this time without active faults. System was thoroughly vacuumed out and wiped down internally. Heat exchanger is beginning to rust internally and externally. Upon arrival I found gas pressures to be over spec by .50 IWC. After adjusting the pressures and checking Induce draft motor I found high amps on IDM based off of Data plate specs. During this visit we spent time going through the report together and have discussed club membership for future service and savings.

Furnace Tune Up 2X
Both systems currently run well. Don had me replace humidifier panels while I was scheduled out and both filters have also been replaced and dated. Measurements are still looking acceptable at this time and both furnaces have been thoroughly vacuumed out and wiped down. During this appointment, Don, Lynn and I spent time discussing details. Lynn and I spent time going over inclusions with the club membership as well. Humidifiers are both turned on and set accordingly for the winter season. There are no major issues to address at this time. Thank you for your business!
What Timnath homeowners are saying
A 5★ average rating from 4 verified reviews.
Great experience! The technician arrived right on time and was very thorough in the explanation of services.
I was so impressed with the service from Long Heating! My technician took the time to fully describe all services performed and didn't pressure upsell of any extras. Highly recommend them and will use them in the future without a doubt!
Second time using Long for my furnace diagnostic and repair needs. This time I had Dylan, who was super knowledgeable and respectful. He told me what was wrong, what my options were and what he suggested. Overall, pricing is really great and I definitely recommend them if you are looking for heating and cooling needs.
Chris did a great job!