Serving Greeley, CO
Local contractor in 80634
Recent projects near 80634
Real work completed for homeowners in Greeley and the surrounding areas.
Furnace Diagnostic
Found bad flame sensor. Replaced flame sensor and tested. Did quick check of ignitor, drain tubes and did carbon monoxide test in home. Everything working and running at this time. Signed up for yearly club membership today. Will have the office call to set up tuneup for furnace. Would prefer a call on either a Thursday or Friday..

Furnace Tune Up
To ensure optimal performance, we conducted a furnace tune-up on a 2017 Amana unit. We thoroughly cleaned the flame sensor, drains, and pressure switch tubing, which are crucial for efficient operation. Additionally, we replaced the air filter to improve air quality. Everything is now clean and running smoothly. Thank you!

Furnace Diagnostic
No heat Found furnace not heating due to clogged drains. Removed all drains and tubing as well as induce draft motor. Cleaned tubes and trap. Tested drains with water and everything flowing freely and draining properly. Thank you!

Furnace Tune Up Member
Performed furnace tune up. Filter was in ok condition and will get replaced by customer. The humidifier pad is in need of replacement. The pad becomes brittle and can leak water during operation, customer will get a #35 humidifier pad ordered. The unit is operating and is heating the house at this time.

Furnace Cleaning
Removed blower wheel assembly. Cleaned out each fin on the wheel. Vacuumed and wiped out the blower compartment. Blew out the motor. Took cleaning spray and covered both the wheel and housing. Rinsed off with water. Assembled back together and tested operation. Unit is clean and was heating upon departure.

Air Conditioner Diagnostic
The outdated Carrier system was struggling due to a restricted evaporator coil, causing the compressor motor to overwork and ultimately failing the run capacitor. We assessed the situation and discussed potential Band-Aid repairs, but given the age and reliance on obsolete R22 refrigerant, we recommended replacing both the furnace and air conditioner for a long-term solution.

Furance Tune Up
Performed furnace tune up. Filter was replaced this month and is clean. Flue pipe from previous fix is still in good condition. Visually inspected the unit and found dust has accumulated on the blower wheel. Cleaning is recommended. I will send estimate. To keep unit from getting dirty after a cleaning, upgrading the filter system will help prevent it. Heat exchanger has some heat stress points. No cracks or fractures were discovered so we will continue to monitor these spots in the coming years. Unit was wiped down and is operating

Heat Pump & Furnace Installation
A significant issue arose requiring a full installation to meet the customer's needs. We expertly executed the installation process while ensuring compliance with necessary office permits. This thorough approach ensured a seamless integration of the new systems without any hitches.

Furnace Tune Up
During the examination, cracks were found in the newly installed heat exchanger of Dennis' 120,000 BTU furnace, which has been functioning at high static pressure. With this system being oversized, the likelihood of future heat exchanger failures is high. We measured carbon monoxide levels at 7 ppm inside the home, identifying a potential hazard. A liability release form was filled out to address these findings.

Furnace Tune Up
System runs flawlessly. Unit is nice and clean internally and ductwork is going to be cleaned right after my visit. No issues to address at this time. Thank you so much for your business.
Furnace Tune Up
A failed heat exchanger in a 1999 furnace was leaking carbon monoxide into the processed air, with measurements registering at 4 PPM. Due to safety concerns, we recommended an immediate replacement of the furnace. Additionally, we discovered that the evaporator coil for the AC was severely rusted, likely releasing R22 vapor into the breathing space of the home. The liability release was signed after reviewing the report during the appointment.
Job in Greeley
The furnace was experiencing intermittent heat, regularly kicking on and off without providing consistent warmth. We conducted a thorough evaluation of the system and found the thermostat was not the issue, leading us to inspect other components to identify the root of the problem. After addressing the underlying issue, the furnace was restored to full functionality.
Job in Greeley
Experiencing issues with the AC, the system wasn’t blowing cold air despite being set to 70 degrees. We conducted a thorough diagnostic for $119, identifying the underlying problem and addressing concerns about warranty coverage. After our assessment, we ensured the system was running efficiently, restoring comfort to the home.

Furnace Tune Up
Performed furnace tune up. Replaced filter with one provided. Like the previous visit the blower wheel and secondary heat exchanger are both dirty. Customer will hold off on cleanings right now. No major issues to address today. System is operating properly and heating at this time. Please see attached form for further details regarding today’s visit.

Furnace Tune Up
Performed furnace tune up on a 1999 comfort maker furnace. The filter was replaced with one provided. The unit is in pretty good shape for its age. Previous owners kept up with maintaining the unit. The blower wheel is dirty, recommend a cleaning. The 5mfd capacitor is reading low. Replacement needed. Other than that the unit is operating properly and heating at this time.

AC Diagnostic
Upon arrival customer stated the unit on the north side of the club house was not running but making a buzzing sound. Performed diagnostics. Checked the capacitor and found it dead. Replaced with new and unit fired up. Checked pressures and temperatures. Temperatures were reading good. Pressures were reading ok but this is due to a dirty coil. Looked for a water source, found one but you need a key to turn the water on. To get the unit to perform better, I recommend having the maintenance guys rinse off the outdoor coil. Recommend doing it for all units in the complex. System is cooling at this time.

Air Conditioner Diagnostic
Upon inspection, we found that while the unit turned on, the outdoor fan was unresponsive. After performing diagnostics, we confirmed the compressor functioned, but the motor was inoperable despite a good capacitor reading. Given the unit's 30-year age, we advised against repairs and provided a quote for a new motor along with suggestions for extending its lifespan. The disconnect was removed to prevent accidental usage.

Furnace And Air Conditioner Maintenance
To ensure optimal performance, we performed a thorough tune-up on the furnace and AC unit. We replaced the filter, wiped down the furnace cabinet, and assessed the blower wheel and heat exchanger. The AC's outdoor coils were rinsed, and refrigerant pressures were confirmed to be good. Both systems are currently functioning well.

A/C Diagnostic
The 2.5 TON air conditioning unit struggled to maintain a comfortable temperature in the 3500 sqft home due to its undersized capacity, especially with the basement included. During our service, we measured refrigerant charge and Delta T, confirming the system's standard operation. Recommendations included closing basement registers and adjusting temperature settings early in the day. Notably, we discovered overheating issues with the 2014 Carrier furnace, suggesting a fall tune-up for optimal performance. We also discussed the importance of regular filter changes for improved efficiency.

Air Conditioner Tune Up
System is a 1996 Lennox currently running on low refrigerant charge. Inside of home I found the evaporator coil to be badly rusted. Rick informed me today that the unit will run and shut off occasionally and he will have to wait in order to allow the system to defrost before he can turn it back on. With rusted evaporator coil refrigerant does not flow in and out of the coil properly any longer. This is an indication of a restriction common for the age. Spent time going through service report with Rick while I was scheduled out. Thank you so much for your business

Air Conditioner Diagnostic
This 2006 Goodman is still currently running fairly well for its age. While I was scheduled out, I did discover that the unit is running on a low refrigerant charge at this time. With a rusted evaporator coil and is currently pulling slightly high amp draw at start. During my presentation, we all spent time discussing details found within this process. These issues are all common for the age on this unit and given what I found system is truly running well for its age. While I was scheduled out, we spent time discussing potential options for charging the unit as well as making a mechanical repair with installation of a compressor saver kit. At this time, system is fully operational and there are no major issues to address. Thank you so much for your business!

A/C Diagnostic
The air conditioner and furnace are both original to the house in 20 years old. The fan motor on the condenser has a failing start winding so sometimes we’ll start and sometimes won’t. The reason why the motor is failing is because of long run times due to low refrigerant. The refrigerant is low because of a severely rusted evaporator coil. Homeowners are discussing options today and will determine if they want to repair or replace and if they choose us, we’ll be calling us back out to get that set up one way or the other.

AC Diagnostic
The air conditioner and furnace are both original to the house in 20 years old. The fan motor on the condenser has a failing start winding so sometimes we’ll start and sometimes won’t. The reason why the motor is failing is because of long run times due to low refrigerant. The refrigerant is low because of a severely rusted evaporator coil. Homeowners are discussing options today and will determine if they want to repair or replace and if they choose us, we’ll be calling us back out to get that set up one way or the other.

A/C Diagnostic
Performed ac tune up. Filter is clean and replaced by customer. The blower wheel is dirty, recommend a cleaning. The indoor unit is pretty clean and operating without issue. The outdoor coils were rinsed off and is clear of cottonwood. The refrigerant pressure are looking great. Fixed the rattling sound customer was concerned about. The condensate vinyl tubing is routed outside. During the winter it’ll freeze causing water to spill onto the ground in the mechanical room. Recommend insulating the tube. If not then rerouting inside to a sink or the washer drain. The unit is currently cooling at this time.

A/C Maintenance
Performed ac tune up. Filter is clean and is replaced by customer. The customer had an error pop up stating the unit has ran for 4 hours but the temp went up 5°. The condenser coils were dirty with cottonwood. Rinsed off and continued my checks. The unit pulls 98 amps during start up, this is very high. With the capacitor running low this can cause high amp draws, contactor also plays a factor in this issue. Both should be replaced. We can also add a hard start kit to lessen the in rush current. The pressures are reading low. This could be due to a possible leak or an improper charge. Customer wants to talk it over amongst each other and see what they want to do. The unit is cooling at this time but may still have issues the hotter it gets.

Air Conditioner Diagnostic
Upon arrival, we discovered a lack of voltage to the outdoor unit caused by melted wiring in the disconnect. After replacing the disconnect and repairing the wires, we tested the system and found a high superheat and properly ranged subcooling. We identified a stuck TXV, which we temporarily unstuck by warming the sensing bulb. The refrigerant charge was confirmed good, but if freezing issues persist, we recommend replacing the TXV. Additionally, a pitted contactor was noted and should be replaced for preventative maintenance. The home had inadequate return airflow, which contributes to uneven temperatures.

Air Conditioner Diagnostic
We identified a disconnect issue with the outdoor AC unit, which was not receiving power despite the installation of good fuses. The electrical circuit did not have a dedicated breaker accessible for resetting. The unit, being 26 years old, also had a rusted coil. We advised the homeowner to consult with a neighbor regarding the electrical circuit and will assist with further diagnostics if needed.

A/C Diagnostic
this 1993 AC has lost pretty much all of its 11+ lb charge of R22 due to a leak. This consequently caused the system to run constantly which unfortunately has led the the blower motor in the 16 year old Rheem furnace inside failing as well. Due to age and obsolete R22 and projected figures for repairs it is not a recomended repair option for the AC at 33 years of age.I have a call out to Supply house for replacement blower motor, blower wheel and run cap. For the furnace. I spent time discussing details regarding repairs on the furnace as well as ball park figures for replacement of the AC only. Thank you for your business!

Air Conditioner Maintenance
During our visit, we identified a failing fan leg on the dual run capacitor, causing a high amp draw that tripped the breaker. After receiving approval, we installed a new run capacitor and assessed the evaporator coil and secondary heat exchanger, which were impacted by inadequate filtration. We recommend replacing the contactor and performing cleanings, though the system’s limitations may hinder effective cooling to the upstairs.

Air Conditioner Diagnostic
Upon inspection of the cooling unit, we found that the compressor was not operating, despite the capacitor being recently replaced. After thorough diagnostics, including checking voltages and bypassing the start thermistor, the compressor remained unresponsive. We installed a hard start kit, and while the compressor attempted to start, it struggled significantly. Ultimately, we determined the compressor failed internally and recommended replacing the unit instead of repairing it, as the costs are comparable. The unit was turned off at the disconnect, and advice was given to keep the indoor blower running.
What Greeley homeowners are saying
A 5★ average rating from 16 verified reviews.
The service tech, Isaac, called to let us know he was on the way, arrived on time and was professional, efficient, competent & friendly. He completed the Furnace check up quickly, made some recommendations about the humidifier and explained their service contract, no hard sell. We're very pleased with the service.
Tech ran a thorough diagnostic and explained everything as they went along. Sent pictures to me and recommended ways to improve my usage without being pushy. Sent over multiple quotes based on different levels of service provided. Overall great experience.
it was a well informed and good call. The serviceman said he would send me a lit of 2-stage thermostatsthat would work with my system to replace the single stage one I have now?
Customer service is exceptional! The whole team is very professional and will answer every question you have. Install was quick, clean, and done right.
These guys have the best technicians and always treat you well
Isaac arrived on time and completed the service call quickly. He was very professional, friendly and competent. The company provides great customer service too.
Excellent workmanship. Polite and concerned craftsman. Price was fair and not at all out of line. Follow up was also Excellent.
Professional-Friendly-Integrity to the highest standard. Phil Long and Staff are exceptional people!
Very respectful. Offered solutions for now and moving forward. Was not pushing any product, which I appreciate. Fixed the problem quickly and was helpful. I will also add that I have used their services for my AC and hot water heater. They have the best receptionist and their timelines has been great. I know exactly when someone is gonna be here.
Luca's is Experience in all areas and very thorough and honest I would recommend long heating .
It’s incredibly refreshing to do business with a company like Long Heating & Air. Their website says they are Honest, Efficient, and Professional. They’re exactly that! We had the pleasure of working with Dylan today. He was thorough and an excellent communicator. He provided long and short term benefits for the different options and his honest and clear approach helped us make an informed decision. I highly recommend this company.
My repairman was friendly, extremely knowledgeable and thorough in the servicing my furnace, very happy with selecting Long Heating and Air.
Chris Ageton at Long Heating & Air Co was great! He was very respectful while completing my a/c tube up. He informed me of his findings and did a wonderful job of making sure that I understood. He made me feel like a valued customer!
I recently purchased a home with a one year old Heat/Air system. The previous owners had not changed the filter and it needed a good cleaning. Chris came out to do the service. He called to give me his arrival time ahead. He did a thorough cleaning and reset the heater temp. He was courteous and professional and charged a fair price. I would recommend LONG Heating and Air.